Deye 8KW Single Phase Hybrid Inverter

$3,645.00

  • Colour LCD, IP65 protection degree, WiFi connectivity
  • 2 MPPT
  • Hybrid Inverter
  • Single Phase
  • Suitable for 48V Battery
  • DC couple and AC couple to retrofitting existing solar system
  • Max. 16pcs parallel for on-grid and off-grid operation; Support multiple batteries in parallel
  • Max. charging/discharging current of 190A
  • 6 time periods for battery charging/discharging
  • 5 Years Warranty
Category:
Brand New - Deye SUN-8K-SG05LP1-AU - supplied by Hi-Cap Energy in Brisbane
Fully CEC compliant - Australian stock
Full spec sheet: 
Technical Specifications
Model SUN-3.6K-SG05LP1-AU SUN-5K-SG05LP1-AU SUN-6K-SG05LP1-AU SUN-7.6K-SG05LP1-AU SUN-8K-SG05LP1-AU
Battery Input Data
Battery Type Lead-acid or Lithium-ion
Battery Voltage Range (V) 40~60
Max. Charging Current (A) 90A 120A 135A 190A 190A
Max. Discharging Current (A) 90A 120A 135A 190A 190A
Charging Curve 3 Stages / Equalization
External Temperature Sensor Yes
Charging Strategy for Li-Ion Battery Self-adaption to BMS
PV String Input Data
Max. DC Input Power (W) 4680W 6500W 7800W 9880W 10400W
PV Input Voltage (V) 370V (125V~500V)
MPPT Voltage Range (V) 150~425V
Start-up Voltage (V) 125V
PV Input Current (A) 13A+13A 26A+26A
Max. PV ISC (A) 17A+17A 34A+34A
No.of MPPT Trackers 2
No.of Strings Per MPPT Tracker 1 2
AC Output Data
Rated AC Output and UPS Power (W) 3600W 5000W 6000W 7600W 8000W
Max. AC Output Power (W) 3690W 5500W 6600W 8360W 8800W
Peak Power (off grid) 2 times of rated power, 10 S
AC Output Rated Current (A) 16.4/15.7 22.7/21.7 27.3/26.1 34.5/33 36.4/34.8
Max. AC Current (A) 18/17.2 25/23.9 30/28.7 38/36.3 40/38.3
Max. Continuous AC Passthrough (A) 35A 40A 50A
Power Factor 0.8 leading to 0.8 lagging
Output Frequency and Voltage 50/60Hz; 220/230 / 240Vac (single phase)
Grid Type Single Phase
Current Harmonic Distortion THD<3% (Linear load<1.5%)
Efficiency
Max. Efficiency 97.60%
Euro Efficiency 96.50%
MPPT Efficiency 99.90%
Protection
PV Input Lightning Protection Integrated
Anti-islanding Protection Integrated
PV String Input Reverse Polarity Protection Integrated
Insulation Resistor Detection Integrated
Residual Current Monitoring Unit Integrated
Output Over Current Protection Integrated
Output Shorted Protection Integrated
Output Over Voltage Protection Integrated
Surge protection DC Type II / AC Type II
Certifications and Standards
Grid Regulation
CEI 0-21, VDE-AR-N 4105, NRS 097, IEC 62116, IEC 61727, G99, G98, VDE 0126-1-1, RD 1699, C10-11
Safety EMC / Standard     IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2
General Data
Operating Temperature Range (℃) -40~60℃, >45℃ Derating
Cooling Natural cooling
Noise (dB) <30 dB
Communication with BMS RS485; CAN
Weight (kg) 24
Size (mm) 330W×580H×232D
Protection Degree IP65
Installation Style Wall-mounted
Warranty 5 years
Shipping
 
We ship Australia wide, generally despatched within 2-5 business days.
 
Pickup is also available from our warehouse in Loganholme 4129 QLD.
 